002135707 ETI Code کلید مینیاتوری ETIMAT10 C 3P 10KA 1/6A Description 0.354kg Weight Miniature circuit breakers MCB Level MCB Function 10 Short circuit capacity (kA) c Tripping characteristic 1,6 Rated current (A) 3 No. Of poles ETIMAT 10 Miniature circuit breakers 10kA Catalogue Group
Logistic data
3838895251910 EAN code product 3838895276838 EAN code basic packaging 3838895276845 EAN code packaging transport 14.288000 kg Weight packaging transport .132 kg Weight product 1.5875555555556 kg Weight basic packaging 12 Qty. basic packaging 108 Qty. packaking 5616 Qty. transport .16111 Basic packaging volume 17.400000 Packaging volume 1879.2 Palete volume 85362010 Customs tariff
ETIM Clasification
AC Voltage type 68mm Built-in depth 6A Nominal rated current 230V Nominal rated voltage 50/60Hz Frequency B Release characteristic V Rated insulation voltage Ui 1 Number of poles 3 Current limiting class 3 Over voltage category 2 Pollution degree Width in number of modular spacings
IP20 Degree of protection (IP) 1 Number of protected poles NO Concurrently switching N-neutral 6 Rated short-circuit breaking capacity EN 60898 yes Suitable for flush-mounted installation mm² Connectable conductor cross section solid-core mm² Connectable conductor cross section multi-wired °C Ambient temperature during operating true Additional equipment possible 1 Number of poles (total) kA Rated short-circuit breaking capacity Icn EN 60898 at 400 V kA Rated short-circuit breaking capacity Icn EN 60898 at 230 V 6kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V kV Rated impulse withstand voltage Uimp -
002111512 ETI Code VLC 8 1P AC22B B20 Description 0.65kg Weight Miniature circuit breakers MCB Level MCB Function 8 Short circuit capacity (kA) B Tripping characteristic 20 Rated current (A) 1 No. Of poles پایه فیوز سیلندری VLC 8 1P AC22B B20 Catalogue Group
Logistic data
3838895251910 EAN code product 3838895276838 EAN code basic packaging 3838895276845 EAN code packaging transport 14.288000 kg Weight packaging transport .132 kg Weight product 1.5875555555556 kg Weight basic packaging 12 Qty. basic packaging 108 Qty. packaking 5616 Qty. transport .16111 Basic packaging volume 17.400000 Packaging volume 1879.2 Palete volume 85362010 Customs tariff
ETIM Clasification
AC Voltage type 68mm Built-in depth 6A Nominal rated current 230V Nominal rated voltage 50/60Hz Frequency B Release characteristic V Rated insulation voltage Ui 1 Number of poles 3 Current limiting class 3 Over voltage category 2 Pollution degree Width in number of modular spacings
IP20 Degree of protection (IP) 1 Number of protected poles NO Concurrently switching N-neutral 6 Rated short-circuit breaking capacity EN 60898 yes Suitable for flush-mounted installation mm² Connectable conductor cross section solid-core mm² Connectable conductor cross section multi-wired °C Ambient temperature during operating true Additional equipment possible 1 Number of poles (total) kA Rated short-circuit breaking capacity Icn EN 60898 at 400 V kA Rated short-circuit breaking capacity Icn EN 60898 at 230 V 6kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V kV Rated impulse withstand voltage Uimp -
002111512 ETI Code VLC 8 1P B 20 AC22B Description 0.65kg Weight Miniature circuit breakers MCB Level MCB Function 8 Short circuit capacity (kA) B Tripping characteristic 20 Rated current (A) 1 No. Of poles پایه فیوز سیلندری VLC 8 1P B 20 AC22B Catalogue Group
Logistic data
3838895251910 EAN code product 3838895276838 EAN code basic packaging 3838895276845 EAN code packaging transport 14.288000 kg Weight packaging transport .132 kg Weight product 1.5875555555556 kg Weight basic packaging 12 Qty. basic packaging 108 Qty. packaking 5616 Qty. transport .16111 Basic packaging volume 17.400000 Packaging volume 1879.2 Palete volume 85362010 Customs tariff
ETIM Clasification
AC Voltage type 68mm Built-in depth 6A Nominal rated current 230V Nominal rated voltage 50/60Hz Frequency B Release characteristic V Rated insulation voltage Ui 1 Number of poles 3 Current limiting class 3 Over voltage category 2 Pollution degree Width in number of modular spacings
IP20 Degree of protection (IP) 1 Number of protected poles NO Concurrently switching N-neutral 6 Rated short-circuit breaking capacity EN 60898 yes Suitable for flush-mounted installation mm² Connectable conductor cross section solid-core mm² Connectable conductor cross section multi-wired °C Ambient temperature during operating true Additional equipment possible 1 Number of poles (total) kA Rated short-circuit breaking capacity Icn EN 60898 at 400 V kA Rated short-circuit breaking capacity Icn EN 60898 at 230 V 6kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V kV Rated impulse withstand voltage Uimp -
002111512 ETI Code پایه فیوز سیلندری VLC 8 1P B20 AC 22B Description 0.65kg Weight Miniature circuit breakers MCB Level MCB Function 8 Short circuit capacity (kA) B Tripping characteristic 20 Rated current (A) 1 No. Of poles پایه فیوز سیلندری VLC 8 1P B20 AC 22B Catalogue Group
Logistic data
3838895251910 EAN code product 3838895276838 EAN code basic packaging 3838895276845 EAN code packaging transport 14.288000 kg Weight packaging transport .132 kg Weight product 1.5875555555556 kg Weight basic packaging 12 Qty. basic packaging 108 Qty. packaking 5616 Qty. transport .16111 Basic packaging volume 17.400000 Packaging volume 1879.2 Palete volume 85362010 Customs tariff
ETIM Clasification
AC Voltage type 68mm Built-in depth 6A Nominal rated current 230V Nominal rated voltage 50/60Hz Frequency B Release characteristic V Rated insulation voltage Ui 1 Number of poles 3 Current limiting class 3 Over voltage category 2 Pollution degree Width in number of modular spacings
IP20 Degree of protection (IP) 1 Number of protected poles NO Concurrently switching N-neutral 6 Rated short-circuit breaking capacity EN 60898 yes Suitable for flush-mounted installation mm² Connectable conductor cross section solid-core mm² Connectable conductor cross section multi-wired °C Ambient temperature during operating true Additional equipment possible 1 Number of poles (total) kA Rated short-circuit breaking capacity Icn EN 60898 at 400 V kA Rated short-circuit breaking capacity Icn EN 60898 at 230 V 6kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V kV Rated impulse withstand voltage Uimp -
002111512 ETI Code VLC 8 1P B20 AC 22B Description 0.128kg Weight Miniature circuit breakers MCB Level MCB Function 8 Short circuit capacity (kA) B Tripping characteristic 20 Rated current (A) 1 No. Of poles پایه فیوز سیلندری VLC 8 1P B20 AC 22B Catalogue Group
Logistic data
3838895251910 EAN code product 3838895276838 EAN code basic packaging 3838895276845 EAN code packaging transport 14.288000 kg Weight packaging transport .132 kg Weight product 1.5875555555556 kg Weight basic packaging 12 Qty. basic packaging 108 Qty. packaking 5616 Qty. transport .16111 Basic packaging volume 17.400000 Packaging volume 1879.2 Palete volume 85362010 Customs tariff
ETIM Clasification
AC Voltage type 68mm Built-in depth 6A Nominal rated current 230V Nominal rated voltage 50/60Hz Frequency B Release characteristic V Rated insulation voltage Ui 1 Number of poles 3 Current limiting class 3 Over voltage category 2 Pollution degree Width in number of modular spacings
IP20 Degree of protection (IP) 1 Number of protected poles NO Concurrently switching N-neutral 6 Rated short-circuit breaking capacity EN 60898 yes Suitable for flush-mounted installation mm² Connectable conductor cross section solid-core mm² Connectable conductor cross section multi-wired °C Ambient temperature during operating true Additional equipment possible 1 Number of poles (total) kA Rated short-circuit breaking capacity Icn EN 60898 at 400 V kA Rated short-circuit breaking capacity Icn EN 60898 at 230 V 6kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V kV Rated impulse withstand voltage Uimp -
002111512 ETI Code پایه فیوز سیلندری VLC 8 1P B20 AC 22B Description 0.128kg Weight Miniature circuit breakers MCB Level MCB Function 8 Short circuit capacity (kA) B Tripping characteristic 20 Rated current (A) 1 No. Of poles پایه فیوز سیلندری VLC 8 1P B20 AC 22B Catalogue Group
Logistic data
3838895251910 EAN code product 3838895276838 EAN code basic packaging 3838895276845 EAN code packaging transport 14.288000 kg Weight packaging transport .132 kg Weight product 1.5875555555556 kg Weight basic packaging 12 Qty. basic packaging 108 Qty. packaking 5616 Qty. transport .16111 Basic packaging volume 17.400000 Packaging volume 1879.2 Palete volume 85362010 Customs tariff
ETIM Clasification
AC Voltage type 68mm Built-in depth 6A Nominal rated current 230V Nominal rated voltage 50/60Hz Frequency B Release characteristic V Rated insulation voltage Ui 1 Number of poles 3 Current limiting class 3 Over voltage category 2 Pollution degree Width in number of modular spacings
IP20 Degree of protection (IP) 1 Number of protected poles NO Concurrently switching N-neutral 6 Rated short-circuit breaking capacity EN 60898 yes Suitable for flush-mounted installation mm² Connectable conductor cross section solid-core mm² Connectable conductor cross section multi-wired °C Ambient temperature during operating true Additional equipment possible 1 Number of poles (total) kA Rated short-circuit breaking capacity Icn EN 60898 at 400 V kA Rated short-circuit breaking capacity Icn EN 60898 at 230 V 6kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V kV Rated impulse withstand voltage Uimp -
002111512 ETI Code ETIMAT 6 1p B6 Description 0.132kg Weight Miniature circuit breakers MCB Level MCB Function 6 Short circuit capacity (kA) B Tripping characteristic 6 Rated current (A) 1 No. Of poles ETIMAT 6 Miniature circuit breakers 6kA Catalogue Group
Logistic data
3838895251910 EAN code product 3838895276838 EAN code basic packaging 3838895276845 EAN code packaging transport 14.288000 kg Weight packaging transport .132 kg Weight product 1.5875555555556 kg Weight basic packaging 12 Qty. basic packaging 108 Qty. packaking 5616 Qty. transport .16111 Basic packaging volume 17.400000 Packaging volume 1879.2 Palete volume 85362010 Customs tariff
ETIM Clasification
AC Voltage type 68mm Built-in depth 6A Nominal rated current 230V Nominal rated voltage 50/60Hz Frequency B Release characteristic V Rated insulation voltage Ui 1 Number of poles 3 Current limiting class 3 Over voltage category 2 Pollution degree Width in number of modular spacings
IP20 Degree of protection (IP) 1 Number of protected poles NO Concurrently switching N-neutral 6 Rated short-circuit breaking capacity EN 60898 yes Suitable for flush-mounted installation mm² Connectable conductor cross section solid-core mm² Connectable conductor cross section multi-wired °C Ambient temperature during operating true Additional equipment possible 1 Number of poles (total) kA Rated short-circuit breaking capacity Icn EN 60898 at 400 V kA Rated short-circuit breaking capacity Icn EN 60898 at 230 V 6kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V kV Rated impulse withstand voltage Uimp -
002111512 ETI Code پایه فیوز سیلندری VLC 8 1P B20 AC 22B Description 0.128kg Weight Miniature circuit breakers MCB Level MCB Function 8 Short circuit capacity (kA) B Tripping characteristic 20 Rated current (A) 1 No. Of poles پایه فیوز سیلندری VLC 8 1P B20 AC 22B Catalogue Group
Logistic data
3838895251910 EAN code product 3838895276838 EAN code basic packaging 3838895276845 EAN code packaging transport 14.288000 kg Weight packaging transport .132 kg Weight product 1.5875555555556 kg Weight basic packaging 12 Qty. basic packaging 108 Qty. packaking 5616 Qty. transport .16111 Basic packaging volume 17.400000 Packaging volume 1879.2 Palete volume 85362010 Customs tariff
ETIM Clasification
AC Voltage type 68mm Built-in depth 6A Nominal rated current 230V Nominal rated voltage 50/60Hz Frequency B Release characteristic V Rated insulation voltage Ui 1 Number of poles 3 Current limiting class 3 Over voltage category 2 Pollution degree Width in number of modular spacings
IP20 Degree of protection (IP) 1 Number of protected poles NO Concurrently switching N-neutral 6 Rated short-circuit breaking capacity EN 60898 yes Suitable for flush-mounted installation mm² Connectable conductor cross section solid-core mm² Connectable conductor cross section multi-wired °C Ambient temperature during operating true Additional equipment possible 1 Number of poles (total) kA Rated short-circuit breaking capacity Icn EN 60898 at 400 V kA Rated short-circuit breaking capacity Icn EN 60898 at 230 V 6kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V kV Rated impulse withstand voltage Uimp -
002111512 ETI Code پایه فیوز سیلندری VLC 8 1P B20 AC 22B Description 0.128kg Weight Miniature circuit breakers MCB Level MCB Function 8 Short circuit capacity (kA) B Tripping characteristic 20 Rated current (A) 1 No. Of poles پایه فیوز سیلندری VLC 8 1P B20 AC 22B Catalogue Group
Logistic data
3838895251910 EAN code product 3838895276838 EAN code basic packaging 3838895276845 EAN code packaging transport 14.288000 kg Weight packaging transport .132 kg Weight product 1.5875555555556 kg Weight basic packaging 12 Qty. basic packaging 108 Qty. packaking 5616 Qty. transport .16111 Basic packaging volume 17.400000 Packaging volume 1879.2 Palete volume 85362010 Customs tariff
ETIM Clasification
AC Voltage type 68mm Built-in depth 6A Nominal rated current 230V Nominal rated voltage 50/60Hz Frequency B Release characteristic V Rated insulation voltage Ui 1 Number of poles 3 Current limiting class 3 Over voltage category 2 Pollution degree Width in number of modular spacings
IP20 Degree of protection (IP) 1 Number of protected poles NO Concurrently switching N-neutral 6 Rated short-circuit breaking capacity EN 60898 yes Suitable for flush-mounted installation mm² Connectable conductor cross section solid-core mm² Connectable conductor cross section multi-wired °C Ambient temperature during operating true Additional equipment possible 1 Number of poles (total) kA Rated short-circuit breaking capacity Icn EN 60898 at 400 V kA Rated short-circuit breaking capacity Icn EN 60898 at 230 V 6kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V kV Rated impulse withstand voltage Uimp -
002111512 ETI Code پایه فیوز سیلندری VLC 8 1P B20 AC 22B Description 0.128kg Weight Miniature circuit breakers MCB Level MCB Function 8 Short circuit capacity (kA) B Tripping characteristic 20 Rated current (A) 1 No. Of poles پایه فیوز سیلندری VLC 8 1P B20 AC 22B Catalogue Group
Logistic data
3838895251910 EAN code product 3838895276838 EAN code basic packaging 3838895276845 EAN code packaging transport 14.288000 kg Weight packaging transport .132 kg Weight product 1.5875555555556 kg Weight basic packaging 12 Qty. basic packaging 108 Qty. packaking 5616 Qty. transport .16111 Basic packaging volume 17.400000 Packaging volume 1879.2 Palete volume 85362010 Customs tariff
ETIM Clasification
AC Voltage type 68mm Built-in depth 6A Nominal rated current 230V Nominal rated voltage 50/60Hz Frequency B Release characteristic V Rated insulation voltage Ui 1 Number of poles 3 Current limiting class 3 Over voltage category 2 Pollution degree Width in number of modular spacings
IP20 Degree of protection (IP) 1 Number of protected poles NO Concurrently switching N-neutral 6 Rated short-circuit breaking capacity EN 60898 yes Suitable for flush-mounted installation mm² Connectable conductor cross section solid-core mm² Connectable conductor cross section multi-wired °C Ambient temperature during operating true Additional equipment possible 1 Number of poles (total) kA Rated short-circuit breaking capacity Icn EN 60898 at 400 V kA Rated short-circuit breaking capacity Icn EN 60898 at 230 V 6kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V kV Rated impulse withstand voltage Uimp -
002111512 ETI Code ETIMAT 6 1p B6 Description 0.132kg Weight Miniature circuit breakers MCB Level MCB Function 6 Short circuit capacity (kA) B Tripping characteristic 6 Rated current (A) 1 No. Of poles ETIMAT 6 Miniature circuit breakers 6kA Catalogue Group
Logistic data
3838895251910 EAN code product 3838895276838 EAN code basic packaging 3838895276845 EAN code packaging transport 14.288000 kg Weight packaging transport .132 kg Weight product 1.5875555555556 kg Weight basic packaging 12 Qty. basic packaging 108 Qty. packaking 5616 Qty. transport .16111 Basic packaging volume 17.400000 Packaging volume 1879.2 Palete volume 85362010 Customs tariff
ETIM Clasification
AC Voltage type 68mm Built-in depth 6A Nominal rated current 230V Nominal rated voltage 50/60Hz Frequency B Release characteristic V Rated insulation voltage Ui 1 Number of poles 3 Current limiting class 3 Over voltage category 2 Pollution degree Width in number of modular spacings
IP20 Degree of protection (IP) 1 Number of protected poles NO Concurrently switching N-neutral 6 Rated short-circuit breaking capacity EN 60898 yes Suitable for flush-mounted installation mm² Connectable conductor cross section solid-core mm² Connectable conductor cross section multi-wired °C Ambient temperature during operating true Additional equipment possible 1 Number of poles (total) kA Rated short-circuit breaking capacity Icn EN 60898 at 400 V kA Rated short-circuit breaking capacity Icn EN 60898 at 230 V 6kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V kV Rated impulse withstand voltage Uimp -
002111512 ETI Code ETIMAT 6 1p B6 Description 0.132kg Weight Miniature circuit breakers MCB Level MCB Function 6 Short circuit capacity (kA) B Tripping characteristic 6 Rated current (A) 1 No. Of poles ETIMAT 6 Miniature circuit breakers 6kA Catalogue Group
Logistic data
3838895251910 EAN code product 3838895276838 EAN code basic packaging 3838895276845 EAN code packaging transport 14.288000 kg Weight packaging transport .132 kg Weight product 1.5875555555556 kg Weight basic packaging 12 Qty. basic packaging 108 Qty. packaking 5616 Qty. transport .16111 Basic packaging volume 17.400000 Packaging volume 1879.2 Palete volume 85362010 Customs tariff
ETIM Clasification
AC Voltage type 68mm Built-in depth 6A Nominal rated current 230V Nominal rated voltage 50/60Hz Frequency B Release characteristic V Rated insulation voltage Ui 1 Number of poles 3 Current limiting class 3 Over voltage category 2 Pollution degree Width in number of modular spacings
IP20 Degree of protection (IP) 1 Number of protected poles NO Concurrently switching N-neutral 6 Rated short-circuit breaking capacity EN 60898 yes Suitable for flush-mounted installation mm² Connectable conductor cross section solid-core mm² Connectable conductor cross section multi-wired °C Ambient temperature during operating true Additional equipment possible 1 Number of poles (total) kA Rated short-circuit breaking capacity Icn EN 60898 at 400 V kA Rated short-circuit breaking capacity Icn EN 60898 at 230 V 6kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V kA Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V kV Rated impulse withstand voltage Uimp